• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
Able Sales logo
Phone Icon1300 793 001 Store Lopcator IconStore Locator Cart Icon
  • Portable Generators
    • Inverter Petrol Generators
    • Petrol Generators
    • Diesel Air Cooled
    • Diesel Water Cooled
    • MINESPEC Portable
    • Accessories & Parts
  • Diesel Generators
    • Generators 6kVA - 20kVA
    • Generators 21kVA - 55kVA
    • Generators 56kVA - 250kVA
    • Generators 251kVA - 1100kVA
    • Synchronised 660kVA - 2200kVA
    • YANMAR Powered Generators
    • KUBOTA Powered Generators
    • CUMMINS Powered Generators
    • ATS - Mains Failure Box
    • Load Banks
    • Alternators
    • Accessories & Parts
    • Filters
  • Renewable Energy
        • Able PAK

          • Portable Power Solutions
          • Battery Power Systems
          • Solar Water Pumps
        • Discover

          • Clever Solutions
          • Inside a PAK
          • Diesel Reduction
          • Maximising Renewables
          • Rapid High Power
        • Support Information

          • My Account
          • About Us
          • Privacy Policy
          • Australia Wide Shipping
          • Terms and Conditions
          • Returns and Exchange Policy
          • Inside Story
          • Testimonials
          • Contact Us
        • Portable Power Stations
        • Solar Water Pumps
  • Fuel Tanks
    • Poly Fuel Tanks
    • Single Wall Fuel Tanks
    • Self Bunded Fuel Tanks
    • Accessories & Parts
  • Lighting Towers
  • Air Compressors
    • Piston Compressors
      • Electric
      • Petrol
      • Diesel
    • Screw Air Compressors
      • Electric
      • Petrol
      • Diesel
    • Portable Air Compressors
    • Air Dryers
    • Accessories & Parts
  • Power Equipment
    • Pressure Washers
      • Electric Pressure Washers
      • Petrol Pressure Washers
      • Diesel Pressure Washers
    • Water Pumps
      • Fire Pumps
        • Fire Pumps Petrol
        • Fire Pumps Diesel
      • Transfer Pumps
        • Transfer Pumps Petrol
        • Transfer Pumps Diesel
      • Stainless Steel Pumps
        • Stainless Steel Pumps Petrol
        • Stainless Steel Pumps Diesel
      • Chemical Transfer Pumps
        • Chemical Pumps Petrol
        • Chemical Pumps Diesel
      • Trash Pumps
        • Trash Pumps Petrol
        • Trash Pumps Diesel
      • Submersible Pumps
      • Accessories & Parts
      • Hose & Fittings
      • Petrol Water Pumps
      • Diesel Water Pumps
    • Engines
      • Petrol
      • Diesel
    • Landscaping
    • Concrete Tools
      • Core Drilling Tools
      • Walk Behind Concrete Saws
      • Concrete Mixer & Power Trowel
    • Hose Crimper
  • Plate Compactors
    • Parts

Able Sales

What is Mine Spec?

May 10, 2024 by chris

Mine Spec refers to modified features or attributes of equipment and machinery to meet the specifications for use in the mining industry.

Although very commonly regarded as vehicle customisations, Mine Spec requirements are often requested for other equipment such as Able Sales diesel generators, fuel tanks, lighting towers and battery energy storage systems (BESS).

How does Mine Spec differ from other industry specifications?

The safety in design considerations for Mine Spec relate to how a products’ use in the Australian mining industry may differ from other industries. Some of these differences relate to:

Proximity of use around very large mobile equipment

  • Safety standards are very often focused on:
    • increased visibility with high-vis colouring, reflective decals, flashing beacons,improved communications capability, and
    • audible warning signals and proximity related detection systems.
  • At Able Sales, many of our smaller, mobile, or transportable equipment and machinery incorporate hi-visable attributes to assist in mitigating any unwanted plant interactions.

Harsh environment

  • Australian mine sites can often be in extreme climates – both very hot and cold, they could be in high humidity, or even very dry, arid locations, and potentially subject to hyper-saline water exposure.
  • The equipment needs to be durable and incorporate high [1]IP rated enclosures and connections such as those in the Able GEN and Able PAK range.

24/7 usage

  • Australian mines and their production are around the clock, for every day of the year.
  • High-visibility markings such as reflective tape or paint that are applied to the equipment and machinery, make them easier to see and recognise in low light and dark conditions.

Remote locations

  • Many mine sites in Australia are located in remote areas away from populated areas. Because of the distances involved and the amount of time that would be spent travelling to provide maintenance service and support, miners want equipment they select for use their site to be very dependable.

Do Australian mines have the same Mine Spec?

No, there is no one-fit-for-all Mine Spec for all Australian mine sites, and the specifications are regularly changing over time.

The requirements of what constitutes Mine Spec comes from both state governments and from the mine owners, all of whom are often reviewing and updating what is their specification expectations as a new Mine Spec.

At Able Sales we have built strong relationships with many major mining companies and have a strong understanding of their Mine Spec – the similarities and the differences.  Listing a few would not adequately convey our extensive customer base and the volume of sales, which are to more than 9,000 customers in Australia in a year. Instead, please contact us directly, and we can discuss your requirements.

Is there one Mine Spec standard?

Standards Australia are documents that are regularly reviewed by technical committees which set out specifications, procedures and guidelines with the aim of having products, services and systems that are safe, consistent and reliable.

Some of these documents are relevant to the mining sectors, with specific references to aspects of plant, equipment and machinery for Australian mine sites.

The updates are with the intent of improving the safety and reliability of plant being used on a mine site.

Our team collaboration throughout the supply chain ensures delivery of products that are to befitting the requirements of customers.

Able GEN Mine Spec diesel generators are designed, built and optimised to operate efficiently and reliably in the harsh conditions experienced in the Australian mining industry.  At Able Sales we understand the changing requirements of powerful and reliable Mine Spec diesel generators for use in mining sites.


[1] IP rating is an ingress protection international rating or code that indicates how well a device, equipment or machinery is protected against water and dust.


Yanmar Low Profile Generator
30 kVA Diesel Generator 415V 38Amps per phase KUBOTA Powered Stamford

Generators – Single or Three Phase?

February 28, 2024 by chris

Should you choose a single phase or a three phase generator for home backup power?

As power loads increase, many think of choosing a three phase generator.

In many aspects this makes sense. Three-phase generators are designed to produce three separate alternating currents, each phase offset by 120 degrees. This design makes them more efficient and capable of providing a stable and consistent power supply.

While they are primarily used for higher power three-phase applications, they can also provide single-phase power output by using a single-phase outlet (which produces one-third of the generator’s power capacity).

However, consideration should be given to the short-term (240V AC) backup power systems and the potential for voltage imbalance.

What is a Three Phase System Voltage Imbalance?

A three-phase system is considered balanced when the phase voltages have the same amplitude and are separated by a phase angle of 120 degrees.  In this ideal scenario, the voltage magnitudes and phase angle differences between the phases are equal.

Voltage imbalance occurs when the three-phase voltages deviate from this balanced state.

It can manifest in different ways, such as a variation in voltage magnitudes (unequal voltages), or a phase angle differences between the phases (unequal phase angles), or a combination of this.

Large single-phase 240V loads are a common cause of a generator’s voltage imbalance.

This is where there is a load on only one phase and neutral (not appearing on the other two phases) or between two phases (current drawn on only two out of the three). An uneven spread of 240V single phase power has the loads drawing current that can lead to slight voltage imbalance.

Considerations in the implications of voltage imbalance.

Unbalanced voltages can cause a phase current imbalance of many times more than the percentage of the voltage imbalance for a fully loaded generator.

Generators operating on imbalanced supplies should be de-rated, resulting in significant reductions in available loading.

Increased losses in power cables due to voltage imbalance may also necessitate cable de-rating.

Single Phase vs Three Phase kVA Generator Sizing

Kilowatts (kW) represent the actual active power used for doing useful work.

Kilovolt-Amperes (kVA) refers to the apparent power. That is, the working power plus the reactive power factor — which does not do the useful work but is necessary to maintain the voltage levels in the system.

The calculation or finding the Required Capacity kVA Rating or Amperage Capacity for Single and Three Phase generator is slightly different.

For a Single Phase 240V unit:

kVA = (V * I) /1000 where V is the voltage as 240V for the Australian household, and I the maximum load current.

As an example: 240V appliances with a 40 maximum amperage load (I), kVA = ( 240 * 40 ) / 1000

This calculates to 9.6 kVA, which we could round up to 10kVA.  A generator such as the Able GEN FP11YS may be suitable in this example.

For a Three Phase unit (powering the same 240V appliances):

kVA = (V * I * 1.732) / 1000 where 1.732 is the simple numerical value for the square root of 3 for the Three Phase distribution, where V is the voltage as 240V for Australian household, and I the maximum load phase current (not current per phase).

Using the same example loading: 240V appliances with a 40 maximum amperage load (I), kVA = ( 240 * 40 *1.732 ) / 1000

This calculates to 16.7 kVA, which we could round up to 17.5kVA.  A generator such as the Able GEN FP19YS may be suitable in this example if loading is constant and well balanced.

In this example, the FP19YS has a prime rating of 25A per phase.  Loading 40A on one phase can’t and shouldn’t happen.  As commented on before regarding imbalance issues: The phase loading needs to be as evenly distributed as possible for example: Phase 1 as 13A, Phase 2 as 13A and Phase 3 as 14A.

IF the load can be balanced in this example, a generator such as the FP19YS can be used.  However, it is important to note that most 240V loads in a general household setting are frequently switch on and off.  Not many turn on and stay on which makes it near impossible to balance these loads within a range of avoiding phase imbalance as described before.

A Three Phase generator such as the LG30IS which is rated at 42A per phase will which on paper will cope with the above example if loaded onto one phase.  However, significant voltage fluctuations on unused phases will occur when loading reaches over 50% of the phase in use if the other phases are not loaded.  The imbalance resulting in a usable power output of 21A from one phase with no loading on other phases.

Keep It Simple!

In summary, maintaining balanced phase voltages is crucial for reliable power, especially those with three-phase generators.

To try and use a Three Phase generator for Single Phase load application has significant complications.

The juggling act of trying to balance phases if using all 3 Phase generator is almost impossible in a household 240V setting and just isn’t worth it!

Voltage imbalance can have significant consequences, affecting motor performance and overall system reliability … if you can keep the loading simple, consider an Able GEN Single Phase 240V generator as the small home or farmhouse power backup system.

Able GEN DC12500E1
11 kVA 240V 46Amps
Trade Spec Petrol Generator
$
2,890
  • 3 x 15 Amp 240V Outlets
  • 13 Continuous Run Time
  • 11,000 Watts
Buy Now
Able GEN FP11YS
11 kVA 240V 42Amps 
Diesel Generator
$
11,500
  • YANMAR Powered
  • 3 × 15Amp 240V outlets
  • Stamford Alternator
Buy Now

Bushfires in Australia – Fire Preparedness is the crisis key

February 15, 2024 by chris

Australia is no stranger to the devastating impact of bushfires, which pose significant threats to life, property, and the environment.  

The 2019-2020 bushfire season, known as Black Summer, was one of the most catastrophic and devastating fire seasons on record in Australia. Many parts of Australia experienced significant fires of uncontrollable dimension as a result of exceptionally hot and dry conditions and a lack of soil moisture. With fires from June 2019 to May 2020, 24.3 million hectares burned, over 3,000 buildings were destroyed and 34 people lost their lives.

With our harsh Australian conditions, it becomes increasingly crucial for residents in fire-prone areas to ensure their homes and properties are prepared for the threat of fire. This commentary looks into the essential equipment households should consider having to provide protection and mitigate risk. For area specific requirements, make sure you contact your local fire authority.

Water pumps and storage –

  • Having an adequate water storage on your property is vital. A water tank, swimming pool or dam can provide a much needed resource during a bushfire or even home fire.
  • Invest in a reliable pump and generator to ensure easy access to water during both bushfires and power outages. At Able Sales we stock a range of Garpen water pumps that are also suited for firefighting. Available in both diesel and petrol models, all models are equipped with time-proven high-performance engines, housed in portable and robust protective frames. Our range of Able GEN portable inverter, petrol and diesel generators are a perfect companion to provide home back up power and an emergency power source during bushfires or other extreme weather events.
  • Install sprinkler systems and/or ensure you have an adequate amount of heavy duty hoses that can reach all areas of your property for dousing flames and wetting down structures.

Fire-resistant building materials –

  • If you are building a new property, it is now a requirement in many areas that you build with fire resistant materials for roofing, walls and decks, this also includes using non-combustible materials such as concrete, brick and steel.
  • Install ember guards in vents and gutter guards to stop leaf and debris build up.

Smoke alarms, fire extinguishers and fire blankets –

  • Install quality smoke alarms in bedrooms, hallways and living areas, ensuring they are tested and have batteries replaced regularly.
  • Keep multiple fire extinguishers strategically placed throughout your home, especially in the kitchen, garage, and near potential ignition sources and ensure family members know how to use them.
  • Fire blankets placed throughout the home and in garages and sheds are crucial to smother small fires and wrap around individuals for protection.

Generators, Portable Power Stations, tools, equipment and clothing –

  • Ensure you have tools to clear brush, trim trees and remove other debris.
  • Equip yourself with rakes, shovels, and chainsaws for creating firebreaks and reducing fuel loads.
  • Have a supply of fire-resistant clothing, boots, gloves, head protection, eye protection and N95 face masks.
  • During an emergency, make sure all of your communication devices such as mobile phones and laptops are fully charged so you can contact fire authorities, family and neighbours. The portable Able GEN generator range allow for easy charging of devices and equipment.  The Able PAK portable power stations can help as an Uninterruptible Power System (UPS) to ensure devices such as fridges, UHF radios and WiFi routers stay active during intermittent power disruptions.
  • Make sure your vehicles have a full tank of fuel and/or are fully charged allowing for quick evacuation.
  • Prepare an evacuation supplies including food, water, medications, clothing and important documents such as passports, birth certificates, wills and insurance documents.  Consider having a “Go Bag” prepared with these contents.

We encourage everyone to get involved in local community fire preparedness events, as your local authorities will always have the most up to date advice and local knowledge to keep both you and your loved ones safe.

Able GEN and Able PRO Fire Protection Equipment

What is Mine Spec?

October 2, 2023 by Oliver

Mine Spec refers to modified features or attributes of equipment and machinery to meet the specifications for use in the mining industry.

Although very commonly regarded as vehicle customisations, Mine Spec requirements are often requested for other equipment such as Able Sales diesel generators, fuel tanks, lighting towers and battery energy storage systems (BESS).

How does Mine Spec differ from other industry specifications?

The safety in design considerations for Mine Spec relate to how a products’ use in the Australian mining industry may differ from other industries. Some of these differences relate to:

Proximity of use around very large mobile equipment

  • Safety standards are very often focused on:
    • increased visibility with high-vis colouring, reflective decals, flashing beacons,improved communications capability, and
    • audible warning signals and proximity related detection systems.
  • At Able Sales, many of our smaller, mobile, or transportable equipment and machinery incorporate hi-visable attributes to assist in mitigating any unwanted plant interactions.

Harsh environment

  • Australian mine sites can often be in extreme climates – both very hot and cold, they could be in high humidity, or even very dry, arid locations, and potentially subject to hyper-saline water exposure.
  • The equipment needs to be durable and incorporate high [1]IP rated enclosures and connections such as those in the Able GEN and Able PAK range.

24/7 usage

  • Australian mines and their production are around the clock, for every day of the year.
  • High-visibility markings such as reflective tape or paint that are applied to the equipment and machinery, make them easier to see and recognise in low light and dark conditions.

Remote locations

  • Many mine sites in Australia are located in remote areas away from populated areas. Because of the distances involved and the amount of time that would be spent travelling to provide maintenance service and support, miners want equipment they select for use their site to be very dependable.

Do Australian mines have the same Mine Spec?

No, there is no one-fit-for-all Mine Spec for all Australian mine sites, and the specifications are regularly changing over time.

The requirements of what constitutes Mine Spec comes from both state governments and from the mine owners, all of whom are often reviewing and updating what is their specification expectations as a new Mine Spec.

At Able Sales we have built strong relationships with many major mining companies and have a strong understanding of their Mine Spec – the similarities and the differences.  Listing a few would not adequately convey our extensive customer base and the volume of sales, which are to more than 9,000 customers in Australia in a year. Instead, please contact us directly, and we can discuss your requirements.

Is there one Mine Spec standard?

Standards Australia are documents that are regularly reviewed by technical committees which set out specifications, procedures and guidelines with the aim of having products, services and systems that are safe, consistent and reliable.

Some of these documents are relevant to the mining sectors, with specific references to aspects of plant, equipment and machinery for Australian mine sites.

The updates are with the intent of improving the safety and reliability of plant being used on a mine site.

Our team collaboration throughout the supply chain ensures delivery of products that are to befitting the requirements of customers.

Able GEN Mine Spec diesel generators are designed, built and optimised to operate efficiently and reliably in the harsh conditions experienced in the Australian mining industry.  At Able Sales we understand the changing requirements of powerful and reliable Mine Spec diesel generators for use in mining sites.


[1] IP rating is an ingress protection international rating or code that indicates how well a device, equipment or machinery is protected against water and dust.


Yanmar Low Profile Generator
30 kVA Diesel Generator 415V 38Amps per phase KUBOTA Powered Stamford

Honda EU70is vs Able GEN IN7500G 7kVA Inverter Generator Comparison

August 14, 2023 by chris

Honda has been known to create some of the best generators on the market. The Honda EU70is is a recent model in their inverter generator range that is selling at approximately $6,999.

There’s no denying that Honda’s established brand is reflected in their premium pricing. With this in mind, some people are starting to look for alternative generators that are considered just as good, but at a lower cost. In fact, Google Trends Australia suggests that searches of the term “cheap generators” is at times much more prevalent than the search term “Honda generators”.

If you are one of those searchers, you might be overwhelmed now by just how many low-cost generators are there on the market. To help you with your buying decision, it’s important to make sure that the performance is not compromised at this price point. At Able Sales, the quality is not compromised. The Able GEN designs are backed by 30 years of experience in the industry.

Check out the portable Able GEN IN7500G inverter generator with its advanced features and specs.

As an alternative to Honda inverter generators see the following as a head-to-head comparison, of the ABLE IN7500G 7kVA inverter generator against the HONDA EU70is 7kVA inverter generator:

Check out the features and specs of each generator below:

7kVA Inverter GeneratorHONDA EU70is Able GEN IN7500G 
Price $6,999$3,490
Maximum Output/
Standby Power
7 kVA7.5kVA
Continuous / Prime Power5.5kVA6.5kVA
Operating HoursApprox 6.5 hr at rated output6.5-10 Hours Continuous 
(load dependant)
Fuel Tank Capacity19.2 Litres25 Litres (ULP)
Size (LxWxH)85x70x72 (cm)95x77x78 (cm)
Dry Weight118.1 kg130 kg
Noise Level54 dBA at 7 Metres (Idle)52 dBA at 7 Metres (Idle)
66 dBA at 7 Meters (3/4 Load)64 dBA at 7 Meters (3/4 Load)
Starting SystemElectricElectric Push Button / Remote (Bluetooth) / Recoil
Fold-down HandlesYesYes
Parallel Operations Connection PortsNoYes

The Verdict:

Both generators are a great choice for mobile businesses, trade events, backup power, or caravanning.

These generators can easily look similar as both are housed in an enclosed frame with lifting bars on top and fold-down handles. They also share some common features and specs, for instance, both come with a push-button electric starter.

However, when you examine each spec closely, you’ll find a slight difference, Able GEN IN7500G has a slightly higher standby and prime power output, a larger fuel tank, and longer operating hours.

What really made the Able GEN IN7500G stands out is that it has a parallel port which Honda EU70is doesn’t have. With its parallel port, you have the option to synchronise two generators to double the power output.

So, if you’re after more power, a larger fuel tank, and a price that doesn’t hurt your wallet, then perhaps Able GEN IN7500G is the way to go!

Able GEN IN7500G
7 kVA Inverter Generator
$
3,490
  • Portable Petrol Generator
  • 27 Amps 240 Volt
  • Electric Start
Buy Now
Able GEN IN7500G Combo
14 kVA Parallel Pack
$
6,900
  • Economy Smart Throttle
  • Super Quiet 52 dBA @ 7m
  • Includes Parallel Box & Cables
Buy Now

Primary Sidebar

Recent Posts

  • Able PAKs: The Game Changing Energy Storage System
  • What is Mine Spec?
  • Power Your Life with an Able PAK005-5
  • Generator Paralleling VS. Synchronised Generators
  • Generators – Single or Three Phase?

Categories

  • Crisis Preparation
  • Generators
  • Mine Spec
  • Portable Generators
  • Renewable Energy
  • Uncategorized

Footer

Able Sales logo
© 2024 Able Power. All Rights Reserved.

Melbourne

Mon-Fri: 8am-5pm
Saturday: Closed
Unit 5/11 Industrial Ave,
Thomastown VIC 3074
(03) 9302 3602
1300 735 902

Brisbane

Mon-Fri: 8am-5pm
Saturday: Closed
Unit 1/8 Prosperity Pl
Park Ridge QLD 4125
(07) 9372 9001
1300 735 840

Perth

Mon-Fri: 8am-5pm
Saturday: 8am-12pm
Unit 3 / 41 Tate St,
Bentley WA 6102
(08) 9358 2299
1300 735 001
angle graphic